Marine Anchor Chain / Swivel Shackle for Bower Anchors

  • Model NO.: kent shackle
  • Standard: GB, ANSI, JIS, ISO
  • Surface Treatment: Galvanized
  • Type: Anchor Chain
  • Proof Load (Kn): Grade2, Grade 3
  • Weight ( Kg/27.5m): 158kg-- 10382kg
  • Linc: Common Linc,Studless Link, Swivel, End Link
  • Certificate: CCS, ABS,Dnv, Lr
  • Trademark: OEM
  • Origin: China
  • Application: Boat, Yacht
  • Customized: Non-Customized
  • Material: Steel
  • Product Name: Marine Anchor Chain / Swivel Shackle
  • Breaking Load (Kn): Grade2, Grade 3
  • Accessories: Jointing Shackle, End Shackle, Kenter Shackles,
  • Condition: New
  • Delivery Time: 30 Days
  • Specification: 16mm---130mm
Marine anchor chain / swivel shackle for bower anchors

Description:

1. The chain cable is to be as required for the calculated equipment number for the vessel. The anchor cable is to be tested to the test loads corresponding to htose for the required chain cable.

2. Where the vessel may anchor in areas where the current exceeds 2.5m/s, the need to provide a length of heavier chain cable locally between the anchor and the rest of the chain to enhance anchor bedding may be required at the discretion of the Classification Society.

3. For certain restricted services the use of steel wire rope may be accepted in place of chain cable at the discretion of the classification society.

4. Grade of chain cables
  Bower anchors are to be associated with stud link chain cables for one of the grades in Table 3.



Table 3 Grades of chain cables
 
Material Grade Range of UTS  (N/mm2)
Mild steel 

Special quality steel

Extra special quality steel 
 
1 


2

3

 
300 to 490 (31÷50 kg/mm2)

490 to 690 (50÷70 kg/mm2)

>690 (> 70 kg/mm2)
 

Proof and breaking loads of stud link chain cables

The design and / or standard breaking loads BL and load PL(expressed in KN) of stud link chain cables are given in Table 4 being d the chain diameter(mm).


Marine Anchor Chain / Swivel Shackle for Bower Anchors 

Axial Flow Fan has a wide range of uses, that is, the airflow in the same direction as the fan blade's axis, such as the electric fan and the external fan of the air conditioner. It is called "axial flow" because the gas flows parallel to the fan shaft. Axial flow fans are usually used in situations with high flow requirements and low pressure requirements. The axial fan is fixed and moves the air. Axial flow fan is mainly composed of fan impeller and casing, with simple structure but high data requirements.

Axial Flow Fan

Axial Flow Fan

ZIBO SUNTAE GLOBAL IMPORT & EXPORT CO.,LTD , https://www.qinengfan.com