Microcomputer Wire Stripping Machine
SF-1006: 1.LCD of man-machine conversation has good performance for emergency and safety guarantee for safe to use and its installation can process in single or double line.
2. wire strip machine which parts can be easily installed and removed.
3. wires Cutting Machine which can reduce cortex press windless to made cable harness more beautiful. Suitable for vsf.lv.kv Glass cables.
SF-600B:1.Micro-computer wire peeling machine adopts microcomputer numerical control device to set the total length of the jumper,accurate accuracy,simple operation and less wear and tear.
2. no waste material,and the length of the die change(h)is adjustable.
3.The whole coil wire is automatically fed and cut without human operation.
4.Accurate accuracy,simple operation and low wear and tear.
5.The use of tungsten carbide molds long life.
6.Quantitative shutdown device.
7. Electronic count caption display.
8.wire peeling machine is easy to adjust,repair and maintain,and adopts special feeding mode.It runs smoothly and does not leave traces on the wire.
9.The length of the foot(H)is fixed.Please specify when ordering.
Ti is suitable for Copper And Iron Jumpers Wire Diameter of 0.5-1mm.Any details about cut and strip cable you want to know please contact us for further more.
Automatic Wire Peel Machine,Cut and Strip Wire,Automatic Computer Stripping Machine,Cable Stripper Machine SINGSUN ELECTRONIC SCIENCE & TECH CO.,LTD , https://www.szsingsunautomatic.com
2. The magnetic flip level gauge must be installed vertically. The ball valve should be installed between the magnetic flip level gauge and the container lead to facilitate inspection and cleaning.
3. If the user uses the heat tracer, he must use non-magnetic materials such as copper tubes. Heating temperature also depends on the medium conditions to determine;
5, magnetic level gauge before use should be calibrated with magnetic steel ball below the zero position is set to red, other balls set to white;
4. The measured medium should not contain solid impurities or magnetic substances, so as to avoid blocking of the float.
6. Open the bottom flange of the magnetic flip level gauge and install the magnetic float (note that the heavy end is magnetically upward and cannot be flipped).
7, should be based on the measurement of the media, from time to time cleaning the main catheter to remove impurities;
8. For level gauges that exceed a certain length, it is necessary to add intermediate reinforcement flanges or ear climbing as a fixed support to increase strength and overcome its own weight;
9, when the commissioning should first open the upper guide valve, and then slowly open the lower valve, so that the media smoothly into the main catheter (runner medium should avoid rapid impact on the float, causing severe fluctuations in the float, affect the accuracy of the display), Observe that the magnetic red-white ball flips are not normal. Then close the down-lead valve and open the drain valve so that the level in the main duct falls. According to this method three times of operation, it is normal, you can put into operation (except for corrosive and other special liquids);
10. The installation position of the magnetic flip liquid level gauge should be avoided or kept away from the inlet and outlet of the material medium, so as to avoid the accuracy of the liquid level measurement due to the rapid change of the local area of ​​the material fluid.
Correct installation of magnetic flap level gauge
1. The magnetic plate level gauge should not be surrounded by magnetically permeable materials, nor can it be fixed by wire, because this will affect the normal operation of the magnetic plate level gauge;