Abstract: Due to the simple structure and easy installation of the vortex flowmeter, the vortex flowmeter can also be used for measurement when measuring compressed air, and also inherits the advantages of the vortex flowmeter , although there are many advantages, but Users will still have various problems during their use. Let's discuss the specific solution together with the problem. 1. The correct selection and scientific installation in the early stage should consider the interference of the surrounding environment signal of the instrument during installation; 2. If the flow of compressed air is only used to control the flow, it can be used routinely. When the interests of the buyer and the seller are involved, the temperature and pressure need to be compensated, that is, the temperature-compensated vortex flowmeter needs to be selected; 3. The Reynolds coefficient of the medium needs to be greater than 2×104 or more, otherwise there will be errors; 4. The nature of the medium to be tested at the time of selection requires the properties of the medium in the actual pipeline to be consistent. If it is inconsistent, it needs to be re-selected according to the nature of the medium in the pipeline; 5. When installing the compressed air flowmeter, keep away from the power source or other frequently changing valves. When the installation pipeline is vibrating, consider installing the fixed bracket on the pipeline, and less errors caused by vibration. 6. If the temperature and pressure compensation type vortex flowmeter is installed, when installing the temperature sensor and the pressure transmitter, the distance of 5~8D downstream of the compressed air flowmeter should be suitable; 7. When the split type compressed air flow meter is selected, our factory will be equipped with a 10 meter cable. When using the cable, use the installed cable and make grounding measures. 8. The load from the signal output of the compressed air flow meter should not exceed the specified value; 9. The installation environment of the compressed air flow meter should try to avoid the environment with high current and strong magnetic field around; Summary: As can be seen from the above analysis, some common problems can be avoided during installation. Therefore, it is recommended to read the installation instructions in detail when purchasing the instrument to avoid unnecessary loss due to improper installation. Tower In Caustic Soda,Caustic Soda Tower,Great Caustic Soda Tower,High Quality Steel Tower Wuxi Mingyan Equipment Co., Ltd , https://www.wxmyzbgroup.com